WV · statewide rule · verified November 5, 2026
West Virginia septic setback requirements
In West Virginia, the septic tank must sit at least 50 ft and the drainfield at least 100 ft from a private well, the drainfield at least 10 ft from the house and 10 ft from the property line. Source: W. Va. Code R. §64-47-6.2 and Table 64-47K ↗. Measure your lot below to see what clears and what does not.
Free lot check
Test your measurements against West Virginia minimums
Enter the distances you measured or read off the site plan. Leave unknown ones blank. Nothing is uploaded.
| Distance to | Septic tank | Drainfield |
|---|---|---|
| Private well | 50 ft | 100 ft |
| House / foundation | 10 ft | 10 ft |
| Property line | 10 ft | 10 ft |
| Surface water | verify locally | 20 ft |
Rule notes
- No part of the system may be within 10 ft of a building, foundation or property line.
- Drainfields need 10 ft from upslope and 20 ft from downslope foundation drains.
- Surface water = stream banks and open drainage features; tank distances to public wells are set by the Commissioner.
Citation: W. Va. Code R. §64-47-6.2 and Table 64-47K · West Virginia sewage system rule 64CSR47 ↗ · Verified against the rule text on November 5, 2026. Spotted a change? Tell us.
Context
How West Virginia compares with other states
- Septic tank → private well: 50 ft is equal to the 50 ft median of 30 tracked states. It matches CDC's 50-ft siting guidance.
- Drainfield → private well: 100 ft is the largest required distance among the 31 states Dakiv tracks. It is stricter than CDC's 50-ft siting guidance.
- Septic tank → house: 10 ft is the largest required distance among the 30 states Dakiv tracks.
- Drainfield → house: 10 ft is equal to the 10 ft median of 32 tracked states.
- Septic tank → property line: 10 ft is the largest required distance among the 30 states Dakiv tracks.
- Drainfield → property line: 10 ft is the largest required distance among the 32 states Dakiv tracks.
- Drainfield → surface water: 20 ft is the smallest minimum among the 30 states Dakiv tracks.
No single statewide value in the cited rule for: septic tank → surface water. Ask the local permit office.
Before you rely on a number
The permit office has the last word.
These are statewide minimums transcribed from W. Va. Code R. §64-47-6.2 and Table 64-47K. Counties, health districts and local boards in West Virginia can require more, and special cases — public wells, shoreland, sensitive aquifers or larger flows — use other distances. Get the approved site plan or as-built for an existing system before you buy, build or add on.
Start with the state program listed in EPA's directory, then confirm the county or district office.
Open the West Virginia permit finderQuick answers
West Virginia septic setback questions
How far does a septic system have to be from a well in West Virginia?
Under W. Va. Code R. §64-47-6.2 and Table 64-47K, the septic tank must be at least 50 feet from a private well and the drainfield at least 100 feet. These are statewide minimums for a private drinking-water well; public wells and local health departments can require more. CDC's national siting guidance is 50 feet.
How close can a septic tank be to a house in West Virginia?
The statewide minimum distance to the house or foundation is 10 feet for the septic tank and 10 feet for the drainfield. Check the notes on this page for basement, crawl-space or footing-drain cases, which often need more room.
How close to the property line can a septic system be in West Virginia?
West Virginia's statewide rule sets 10 feet for the tank and 10 feet for the drainfield from the property line. Easements, neighbouring wells and local ordinances can push the system further in.
How far must a septic system be from a lake or stream in West Virginia?
The statewide minimum to surface water is 20 feet for the drainfield. Shoreland, watershed and drinking-water-supply areas often carry larger buffers.
Can my county require larger septic setbacks than West Virginia's state rule?
Yes. These are statewide minimums. County health departments, districts and local boards can adopt stricter distances, and the permit office that controls your parcel has the final say. Use the permit finder to reach it before you buy, build or add on.