30 state rules · verified November 5, 2026

How far must a septic system be from a lake or stream?

It depends on the state. Across the 30 state rules Dakiv tracks, the minimum from the septic tank to a lake, stream or other surface water is 10–100 ft and from the drainfield 20–100 ft. The most common tank distance is 50 ft (11 states). Your county can require more.

Septic tank10–100 ftstatewide minimums
Drainfield20–100 ftstatewide minimums
Most common50 fttank · 11 states
States cited30official rule text

Quick check

Does your layout clear the minimum?

Pick your state and enter a distance.Nothing is uploaded.
Run the full property screen →

State by state

Bars: drainfield (dark) and septic tank (light), in feet. Labels show tank / drainfield. Click a state for its full rules.

Distance to surface water by state

Minimum drainfield distance (tank where no drainfield value) to the water, in feet. 32 states with a cited statewide rule; tap a state for its full rules.

20–24 ft25–49 ft50–74 ft75–100 ftNot covered

Measuring it correctly

  • Most rules measure from the ordinary or mean high-water mark, not the water edge on the day you visit.
  • Wetlands, drainage ditches and intermittent streams can carry their own, different distances.
  • Lakefront lots are where local shoreland ordinances most often exceed the state minimum.

Surface-water setbacks protect lakes, streams and wetlands from nutrients and bacteria. Shoreland zoning and drinking-water watersheds commonly add larger local buffers.

Statewide minimum distance to surface water (verified 2026-11-05)
StateSeptic tankDrainfieldRule
Arizona100 ft100 ftA.A.C. R18-9-A312(C)
Arkansas100 ft100 ftArkansas Dept. of Health Onsite Wastewater Rules, §6.2
Colorado50 ft50 ft5 CCR 1002-43, §43.7 Table 7-1
Florida75 ft75 ftRule 62-6.005, F.A.C. (formerly 64E-6.005)
Georgiaverify locally50 ftGa. Comp. R. & Regs. 511-3-1-.07(3)
Indiana25 ft25 ft410 IAC 6-8.3-57, Table I
Kansas50 ft50 ftK.A.R. 28-5-2; KDHE Bulletin 4-2, Table 5
Kentucky25 ft25 ft902 KAR 10:085, Section 8, Table 7
Maine100 ft100 ft10-144 CMR Ch. 241, §8, Table 8B
Massachusetts25 ft50 ft310 CMR 15.211 (Title 5)
Mississippiverify locally50 ft15 Miss. Admin. Code Pt. 18, Subpt. 77, R. 5.1.3 and R. 5.4.4
Missouri50 ft50 ft19 CSR 20-3.060, Table 1
Montanaverify locally100 ftARM 17.36.323, Table 2
Nebraska50 ft50 ft124 NAC ch. 2, §011, Table 2.1
Nevada100 ft100 ftNAC 445A.965
New Jersey25 ft50 ftN.J.A.C. 7:9A-4.3, Table 4.3
New Mexico50 ft100 ft20.7.3.302 NMAC, Table 302.1
New York50 ft100 ft10 NYCRR Appendix 75-A.4, Table 2
North Carolina50 ft50 ft15A NCAC 18E .0601, Table IX
Ohioverify locally50 ftOAC 3701-29-06(G)(3)
Oregon50 ft100 ftOAR 340-071-0220, Table 1
Pennsylvania25 ft50 ft25 Pa. Code §73.13
South Carolina75 ft75 ftS.C. Code Regs. 61-56.200.6(1)
Tennessee15 ft25 ftTenn. Comp. R. & Regs. 0400-48-01-.11
Texas50 ft75 ft30 TAC §285.91(10), Table X
Utah25 ft100 ftUtah Admin. Code R317-4-13, Table 2
Washington50 ft100 ftWAC 246-272A-0210, Table IV
West Virginiaverify locally20 ftW. Va. Code R. §64-47-6.2 and Table 64-47K
Wisconsin10 ft50 ftWis. Admin. Code SPS 383.43, Table 383.43-1; well distances NR 812.08
Wyoming50 ft50 ftWY DEQ Water Quality Rules Ch. 25, §7, Table 4

Quick answers

Questions about distance to surface water

How far must a septic system be from a lake or stream?

It depends on the state. Across the 30 state rules Dakiv tracks, the minimum from the septic tank to a lake, stream or other surface water is 10–100 ft and from the drainfield 20–100 ft. The most common tank distance is 50 ft (11 states). Your county can require more.

Is the drainfield distance to surface water different from the septic tank distance?

Usually yes. The tank is a sealed container, so many states allow it closer than the drainfield, which releases effluent into the soil. In 11 of the 30 tracked states the drainfield needs more distance than the tank.

What if my state is not listed?

Some states leave these distances to counties or districts, and Dakiv only lists states whose statewide rule we could cite directly. Use the permit finder to reach the office that controls your parcel; it has the binding number.