NV ยท statewide rule ยท verified November 5, 2026

Nevada septic setback requirements

In Nevada, the septic tank must sit at least 100 ft from a private well, the drainfield at least 10 ft from the house and 10 ft from the property line. Source: NAC 445A.965 โ†—. Measure your lot below to see what clears and what does not.

Private well100 ftseptic tank
House / foundation10 ftdrainfield
Property line10 ftdrainfield
Surface water100 ftdrainfield

Free lot check

Test your measurements against Nevada minimums

Enter the distances you measured or read off the site plan. Leave unknown ones blank. Nothing is uploaded.

Enter at least one distance.Each row turns green when it clears the statewide minimum and red when it falls short.
Run the full property screen with Nevada rules โ†’
Nevada statewide minimum horizontal setbacks in feet (verified 2026-11-05)
Distance toSeptic tankDrainfield
Private well100 ftverify locally
House / foundation10 ft10 ft
Property line10 ft10 ft
Surface water100 ft100 ft

Rule notes

  • Disposal field to a domestic well is 100 ft if the well is sealed to 50 ft and 150 ft if it is not.
  • The state may increase well distances for high water tables, soils, nitrogen or wellhead protection areas.
  • Washoe and Clark counties run their own programs with local rules.

Citation: NAC 445A.965 ยท Nevada Administrative Code 445A.965, setbacks โ†— ยท Verified against the rule text on November 5, 2026. Spotted a change? Tell us.

Context

How Nevada compares with other states

  • Septic tank โ†’ private well: 100 ft is the largest required distance among the 30 states Dakiv tracks. It is stricter than CDC's 50-ft siting guidance.
  • Septic tank โ†’ house: 10 ft is the largest required distance among the 30 states Dakiv tracks.
  • Drainfield โ†’ house: 10 ft is equal to the 10 ft median of 32 tracked states.
  • Septic tank โ†’ property line: 10 ft is the largest required distance among the 30 states Dakiv tracks.
  • Drainfield โ†’ property line: 10 ft is the largest required distance among the 32 states Dakiv tracks.
  • Septic tank โ†’ surface water: 100 ft is the largest required distance among the 25 states Dakiv tracks.
  • Drainfield โ†’ surface water: 100 ft is the largest required distance among the 30 states Dakiv tracks.

No single statewide value in the cited rule for: drainfield โ†’ private well. Ask the local permit office.

Before you rely on a number

The permit office has the last word.

These are statewide minimums transcribed from NAC 445A.965. Counties, health districts and local boards in Nevada can require more, and special cases โ€” public wells, shoreland, sensitive aquifers or larger flows โ€” use other distances. Get the approved site plan or as-built for an existing system before you buy, build or add on.

Find who permits septic systems for your parcel.

Start with the state program listed in EPA's directory, then confirm the county or district office.

Open the Nevada permit finder

EPA state program contact โ†—

Quick answers

Nevada septic setback questions

How far does a septic system have to be from a well in Nevada?

Under NAC 445A.965, the septic tank must be at least 100 feet from a private well. These are statewide minimums for a private drinking-water well; public wells and local health departments can require more. CDC's national siting guidance is 50 feet.

How close can a septic tank be to a house in Nevada?

The statewide minimum distance to the house or foundation is 10 feet for the septic tank and 10 feet for the drainfield. Check the notes on this page for basement, crawl-space or footing-drain cases, which often need more room.

How close to the property line can a septic system be in Nevada?

Nevada's statewide rule sets 10 feet for the tank and 10 feet for the drainfield from the property line. Easements, neighbouring wells and local ordinances can push the system further in.

How far must a septic system be from a lake or stream in Nevada?

The statewide minimum to surface water is 100 feet for the tank and 100 feet for the drainfield. Shoreland, watershed and drinking-water-supply areas often carry larger buffers.

Can my county require larger septic setbacks than Nevada's state rule?

Yes. These are statewide minimums. County health departments, districts and local boards can adopt stricter distances, and the permit office that controls your parcel has the final say. Use the permit finder to reach it before you buy, build or add on.